2.7 KiB
2.7 KiB
Validation — 2026-09-20
Host: Aurora 44; libfprint 1.94.100-1.fc44; fprintd 1.94.5-5.fc44.
Completed:
cargo build --release --offline --locked— passed; executable attarget/release/fingerprint-switch.cargo test --offline --locked— 24 passed: 12 private-D-Bus lifecycle tests, 8 routing tests, 3 reader-selection tests, 1 CLI validation test. Mock buses require permission to create local sockets. They do not use the system fprintd or write biometrics.cargo clippy --all-targets --offline --locked -- -D warnings— passed.cargo fmt --check— passed.- Shell syntax checks and ShellCheck for both installer scripts — passed.
systemd-analyze verify— passed for temporary copies of both service units and the fprintd drop-in together. The staged unit's executable path was replaced with the built workspace binary solely for this check. Nothing was installed.- Final release
probe --sensor external— real Microarray reader opened and released successfully through fprintd; no enrollment. - Final release
probe --sensor internal— real Goodix reader opened and released successfully through fprintd; no enrollment. - Final release
status— detected both readers, open lid, and selected Goodix for CLI auto mode. Goodix still listed its three existing finger enrollments; Microarray listed none. - ELF interpreter and dependencies resolve to system
/lib64libraries, so the binary does not depend on a Homebrew path hidden by the systemd service'sProtectHomesetting.
Not yet performed:
- Real enrollment, matching and rejection with a person touching each sensor.
- Installing/starting the watcher or changing host authentication configuration.
- Physical lid-close/open and USB-unplug routing with the installed service.
The tests validate policy and error handling; they do not establish fingerprint matching accuracy or prove the uninstalled system integration end to end.
Suggested hands-on check after enrollment and opt-in installation:
- Verify the enrolled finger on each reader using explicit CLI selection while
both readers are exposed (
mode bothif the watcher is installed). - Check rejection with a different, unenrolled finger on each reader.
- Set
mode auto, keep the lid open and confirmlistexposes Goodix. - Close the lid while docked and awake; confirm Microarray is exposed and can authenticate. Existing system power settings still determine suspend behavior.
- Reopen the lid and confirm Goodix returns. Unplug the USB reader and check fallback. Keep a password-based session available while testing.
- Verify an ordinary configured fingerprint authentication flow, such as the screen lock or sudo, then test the uninstall script if rollback is desired.