Add fingerprint reader selection and lid-based routing
This commit is contained in:
@@ -0,0 +1,50 @@
|
||||
# Validation — 2026-09-20
|
||||
|
||||
Host: Aurora 44; libfprint `1.94.100-1.fc44`; fprintd `1.94.5-5.fc44`.
|
||||
|
||||
Completed:
|
||||
|
||||
- `cargo build --release --offline --locked` — passed; executable at
|
||||
`target/release/fingerprint-switch`.
|
||||
- `cargo test --offline --locked` — **24 passed**: 12 private-D-Bus lifecycle
|
||||
tests, 8 routing tests, 3 reader-selection tests, 1 CLI validation test.
|
||||
Mock buses require permission to create local sockets. They do not use the
|
||||
system fprintd or write biometrics.
|
||||
- `cargo clippy --all-targets --offline --locked -- -D warnings` — passed.
|
||||
- `cargo fmt --check` — passed.
|
||||
- Shell syntax checks and ShellCheck for both installer scripts — passed.
|
||||
- `systemd-analyze verify` — passed for temporary copies of both service units
|
||||
and the fprintd drop-in together. The staged unit's executable path was replaced
|
||||
with the built workspace binary solely for this check. Nothing was installed.
|
||||
- Final release `probe --sensor external` — real Microarray reader opened and
|
||||
released successfully through fprintd; no enrollment.
|
||||
- Final release `probe --sensor internal` — real Goodix reader opened and
|
||||
released successfully through fprintd; no enrollment.
|
||||
- Final release `status` — detected both readers, open lid, and selected Goodix
|
||||
for CLI auto mode. Goodix still listed its three existing finger enrollments;
|
||||
Microarray listed none.
|
||||
- ELF interpreter and dependencies resolve to system `/lib64` libraries, so the
|
||||
binary does not depend on a Homebrew path hidden by the systemd service's
|
||||
`ProtectHome` setting.
|
||||
|
||||
Not yet performed:
|
||||
|
||||
- Real enrollment, matching and rejection with a person touching each sensor.
|
||||
- Installing/starting the watcher or changing host authentication configuration.
|
||||
- Physical lid-close/open and USB-unplug routing with the installed service.
|
||||
|
||||
The tests validate policy and error handling; they do not establish fingerprint
|
||||
matching accuracy or prove the uninstalled system integration end to end.
|
||||
|
||||
Suggested hands-on check after enrollment and opt-in installation:
|
||||
|
||||
1. Verify the enrolled finger on each reader using explicit CLI selection while
|
||||
both readers are exposed (`mode both` if the watcher is installed).
|
||||
2. Check rejection with a different, unenrolled finger on each reader.
|
||||
3. Set `mode auto`, keep the lid open and confirm `list` exposes Goodix.
|
||||
4. Close the lid while docked and awake; confirm Microarray is exposed and can
|
||||
authenticate. Existing system power settings still determine suspend behavior.
|
||||
5. Reopen the lid and confirm Goodix returns. Unplug the USB reader and check
|
||||
fallback. Keep a password-based session available while testing.
|
||||
6. Verify an ordinary configured fingerprint authentication flow, such as the
|
||||
screen lock or sudo, then test the uninstall script if rollback is desired.
|
||||
Reference in New Issue